Quick answer
Oregon and Washington plumbing exams are based on the Uniform Plumbing Code with state amendments. Expect traps and venting, drainage slope, backflow prevention, water heaters, testing and pipe sizing. Oregon licenses plumbers through the Building Codes Division and Washington certifies them through L&I.
Practice only. Not an official test.
These are original practice questions written by PITHE Digital Group for study purposes, based on public laws, codes and agency guidance. They are not real or past exam questions, and this page is not affiliated with, endorsed by or sponsored by the Oregon Building Codes Division, Washington Labor & Industries, IAPMO or any testing company or any testing company. A score here does not predict your real exam result and does not give you any license, permit, card or certificate.
Laws, codes and fees change, and mistakes are possible. Always confirm with the official agency and your approved course materials. This is general educational information, not legal or professional advice. Read the full disclaimer.
Exam facts are from public agency sources as of November 7, 2026. Confirm current details with the official agency before you schedule.
Oregon and Washington both base their plumbing rules on the Uniform Plumbing Code with state amendments. Oregon licenses plumbers through the Building Codes Division, and Washington certifies them through L&I. Practice the essentials here.
How it works: tap an answer to see if you got it right, why, and the law or code it comes from. Your progress saves on this device only, so you can bookmark the page and pick up later. No signup, no card.
Jump to: Traps and venting · Drainage · Water supply and backflow · Water heaters · Licensing and practice
Traps and venting
Practice question 1 · Traps and venting
What trap seal depth does the Uniform Plumbing Code require?
Answer: A. Not less than 2 inches and not more than 4 inches Trap seals must be between 2 and 4 inches deep.Source: Uniform Plumbing Code (UPC) Chapter 10, trap seals
Practice question 2 · Traps and venting
Which trap is prohibited?
Answer: C. Full S-trap S-traps, bell traps and crown-vented traps are prohibited because they siphon or clog easily.Source: UPC Chapter 10, prohibited traps
Practice question 3 · Traps and venting
What is the main purpose of a vent?
Answer: B. To protect trap seals from siphonage and back pressure and let air into the drainage system Vents keep air pressure balanced so trap seals stay intact.Source: UPC Chapter 9
Practice question 4 · Traps and venting
Can a fixture be double-trapped?
Answer: D. No, a fixture shall not be double-trapped Two traps in series cause air lock and slow drainage.Source: UPC Chapter 10, traps
Practice question 5 · Traps and venting
How far must a vent pipe extend above the roof?
Answer: D. At least 6 inches Vent pipes terminate vertically at least 6 inches above the roof, more where local snow or roof-use rules apply.Source: UPC Chapter 9, vent termination
Practice question 6 · Traps and venting
A vent terminal is near an openable window. What is the rule?
Answer: C. At least 10 feet horizontally away, unless it is at least 3 feet above the window Keep vents 10 feet from openable windows, doors and air intakes, or 3 feet above them.Source: UPC Chapter 9, vent termination
Practice question 7 · Traps and venting
What is a wet vent?
Answer: B. A vent that also carries drainage from other fixtures Wet venting is allowed in specific arrangements where a drain line also serves as a vent.Source: UPC Chapter 9, wet venting
Practice question 8 · Traps and venting
Why do dry vents need to be graded?
Answer: C. So condensation and water drain back by gravity to the drainage pipe Vents are installed so moisture drains back into the system.Source: UPC Chapter 9
Drainage
Practice question 9 · Drainage
What is the standard minimum slope for horizontal drainage piping?
Answer: C. 1/4 inch per foot The usual minimum is 1/4 inch per foot. Larger pipes may be allowed at 1/8 inch per foot only where approved.Source: UPC Chapter 7, grade of horizontal drainage piping
Practice question 10 · Drainage
A horizontal drain runs 40 feet at 1/4 inch per foot. How much total fall?
Answer: D. 10 inches 40 x 1/4 inch = 10 inches.Source: Plumbing math
Practice question 11 · Drainage
What is a drainage fixture unit (DFU)?
Answer: A. A measure of the load a fixture puts on the drainage system DFUs are used to size drains and vents based on how much each fixture discharges.Source: UPC Chapter 7
Practice question 12 · Drainage
What is the main purpose of a cleanout?
Answer: C. To give access for clearing blockages in drain piping Cleanouts let you clear drains without cutting pipe. Keep them accessible.Source: UPC Chapter 7, cleanouts
Practice question 13 · Drainage
What is a grease interceptor for?
Answer: B. Separating fats, oils and grease from wastewater before it reaches the sewer Grease interceptors protect sewers from FOG buildup in food service.Source: UPC Chapter 10
Practice question 14 · Drainage
How is a DWV system commonly tested with water?
Answer: A. With at least a 10-foot head of water A water test uses at least a 10-foot head. An air test uses 5 psi held for 15 minutes.Source: UPC Chapter 7, testing
Practice question 15 · Drainage
What air pressure is used for an air test of a DWV system?
Answer: A. 5 psi for 15 minutes The UPC air test is 5 psi with no drop for 15 minutes.Source: UPC Chapter 7, testing
Water supply and backflow
Practice question 16 · Water supply and backflow
When must a pressure-reducing valve be installed on a building water supply?
Answer: A. When street pressure exceeds 80 psi Install a PRV where static pressure is over 80 psi, and keep the downstream pressure at 80 psi or less.Source: UPC 608.2
Practice question 17 · Water supply and backflow
What is a cross-connection?
Answer: A. A connection where non-drinkable water or substances could get into the drinking water supply Cross-connections are controlled with backflow prevention devices or air gaps.Source: UPC Chapter 6; EPA cross-connection control guidance
Practice question 18 · Water supply and backflow
How big must an air gap be?
Answer: B. At least twice the diameter of the effective opening, and never less than 1 inch The air gap is twice the opening's diameter, at least 1 inch.Source: UPC Chapter 6, air gaps
Practice question 19 · Water supply and backflow
Which backflow device is used for high-hazard connections under continuous pressure?
Answer: D. Reduced pressure principle assembly (RP) RP assemblies protect against backpressure and backsiphonage for high hazards.Source: UPC Chapter 6, backflow prevention assemblies
Practice question 20 · Water supply and backflow
How high must an atmospheric vacuum breaker be above the highest downstream outlet?
Answer: D. At least 6 inches AVBs must be at least 6 inches above the highest outlet and never under continuous pressure.Source: UPC Chapter 6, vacuum breakers
Practice question 21 · Water supply and backflow
What does a water hammer arrestor do?
Answer: C. Absorbs the pressure surge when a valve closes quickly Quick-closing valves in washers and dishwashers cause banging. Arrestors absorb the shock.Source: UPC Chapter 6, water hammer
Practice question 22 · Water supply and backflow
About how much pressure does a 20-foot column of water create at the bottom?
Answer: C. About 8.7 psi Water creates 0.433 psi per foot. 20 x 0.433 = about 8.7 psi.Source: Hydraulics (1 psi = 2.31 feet of head)
Practice question 23 · Water supply and backflow
What is the maximum lead content allowed in solder and flux for drinking water systems?
Answer: C. 0.2% "Lead free" solder and flux may contain no more than 0.2% lead.Source: Safe Drinking Water Act Section 1417
Practice question 24 · Water supply and backflow
Why use a dielectric fitting between copper and galvanized steel?
Answer: B. To prevent galvanic corrosion between dissimilar metals Dissimilar metals in contact with water corrode quickly without isolation.Source: General plumbing practice; UPC Chapter 3
Water heaters
Practice question 25 · Water heaters
What does a temperature and pressure (T&P) relief valve do?
Answer: D. Opens to release water if temperature or pressure gets dangerously high The T&P valve keeps a tank from turning into a bomb. Never cap or plug it.Source: UPC 608.3
Practice question 26 · Water heaters
Where must a T&P relief discharge pipe terminate?
Answer: C. Not more than 24 inches and not less than 6 inches above the floor, or to an approved location, with no trap or valve The discharge pipe is full size, has no valves or traps, and ends 6 to 24 inches above the floor or other approved location.Source: UPC 608, relief valve discharge
Practice question 27 · Water heaters
How must water heaters be braced in the earthquake-prone Pacific Northwest?
Answer: B. Straps in the upper third and lower third of the tank, the lower strap at least 4 inches above the controls Seismic straps keep the tank from tipping and breaking gas or water lines.Source: UPC Chapter 5, seismic restraint of water heaters
Practice question 28 · Water heaters
When is a thermal expansion tank needed?
Answer: D. When a check valve, PRV or backflow device creates a closed system In a closed system, heated water has nowhere to expand, so pressure climbs without a tank.Source: UPC 608.3
Practice question 29 · Water heaters
What is the maximum outlet temperature for shower and tub-shower mixing valves?
Answer: D. 120 degrees F Shower and tub-shower valves must be adjusted to a maximum of 120 degrees F to prevent scalding.Source: UPC Chapter 4, shower and tub-shower valves
Licensing and practice
Practice question 30 · Licensing and practice
Which agency handles plumbing licenses in Oregon?
Answer: B. The Building Codes Division (State Plumbing Board) Oregon BCD and the State Plumbing Board license plumbers. Plumbing contractors also need a CCB license.Source: Oregon Building Codes Division
Practice question 31 · Licensing and practice
Which agency certifies plumbers in Washington?
Answer: D. Labor and Industries (L&I) Washington L&I issues plumber certificates and runs the exams.Source: Washington State Department of Labor & Industries
Practice question 32 · Licensing and practice
Which plumbing code do Oregon and Washington base their rules on?
Answer: D. The Uniform Plumbing Code, with state amendments Both states adopt the UPC with state amendments. Always check the current state edition.Source: Oregon Plumbing Specialty Code; WAC 51-56
Practice question 33 · Licensing and practice
PEX tubing should be protected from what during storage and installation?
Answer: A. Direct sunlight (UV) UV exposure damages PEX. Follow the manufacturer's limits on sun exposure.Source: Manufacturer installation standards; UPC Chapter 6
Practice score only. This is not an official result and does not predict how you will do on the real exam.
Starting your own plumbing business? We list plumbers free and build websites that get emergency calls.
How to pass: study tips that work
- Memorize the everyday numbers: 2 to 4 inch trap seal, 1/4 inch per foot slope, 80 psi PRV, 6 to 24 inch T&P discharge.
- Practice using DFU tables to size drains and vents.
- Know each backflow device and the hazard it is for.
- Study your state's amendments, not just the base UPC.
Official sources to study from
Use the official materials and approved courses as your real guide. These links go to the agencies, not to us.
See a mistake or an outdated rule? Tell us and we will check it against the official source and fix it.
More free practice tests
Common questions
Which plumbing code do Oregon and Washington use?
Both adopt the Uniform Plumbing Code with state amendments.
Who licenses plumbers in Oregon and Washington?
Oregon's Building Codes Division (State Plumbing Board) and Washington's Department of Labor and Industries.
Are these real Plumbing (UPC) exam questions?
No. They are original practice questions written by PITHE Digital Group from public laws, codes and agency guidance. They are not real or past exam questions, and we are not affiliated with the Oregon Building Codes Division, Washington Labor & Industries, IAPMO or any testing company or any testing company.
Does passing this Plumbing (UPC) practice test give me a license or certificate?
No. This free practice test is for study only. You must complete the official requirements and pass the official exam through the agency or its approved provider.
Is this practice test free?
Yes. It is free with no signup. Your progress saves only on your device.
Save this page. Bookmark it (on iPhone tap Share, then Add Bookmark) or send it to someone starting out.
Want customers to find you, too?
List your business free, or get a free website mockup and a written quote from our Pacific Northwest team.