Quick answer
EPA Section 608 certification is required to buy refrigerant and service equipment that contains it. The exam has a Core section plus Type I, II and III. Each section has 25 questions, you need 18 correct to pass, and certification does not expire.
Practice only. Not an official test.
These are original practice questions written by PITHE Digital Group for study purposes, based on public laws, codes and agency guidance. They are not real or past exam questions, and this page is not affiliated with, endorsed by or sponsored by the U.S. EPA or any EPA-approved certifying organization or any testing company. A score here does not predict your real exam result and does not give you any license, permit, card or certificate.
Laws, codes and fees change, and mistakes are possible. Always confirm with the official agency and your approved course materials. This is general educational information, not legal or professional advice. Read the full disclaimer.
Exam facts are from public agency sources as of November 7, 2026. Confirm current details with the official agency before you schedule.
You need EPA Section 608 certification to buy refrigerant and work on systems that contain it. Each section of the exam has 25 questions and you need 18 right. Start with the Core section here.
How it works: tap an answer to see if you got it right, why, and the law or code it comes from. Your progress saves on this device only, so you can bookmark the page and pick up later. No signup, no card.
Jump to: Ozone and the law · Recovery, recycling and reclaiming · Safety and service · Certification types
Ozone and the law
Practice question 1 · Ozone and the law
Which element in CFC and HCFC refrigerants damages the ozone layer?
Answer: D. Chlorine Chlorine released in the stratosphere breaks down ozone molecules.Source: EPA, Ozone layer protection
Practice question 2 · Ozone and the law
Where is the protective ozone layer?
Answer: B. Stratosphere The stratospheric ozone layer blocks harmful UV radiation.Source: EPA, Ozone layer protection
Practice question 3 · Ozone and the law
What international agreement phased out ozone-depleting substances?
Answer: B. The Montreal Protocol The Montreal Protocol (1987) led to phasing out CFCs and HCFCs.Source: EPA, Montreal Protocol
Practice question 4 · Ozone and the law
Which section of the Clean Air Act covers refrigerant handling by technicians?
Answer: B. Section 608 Section 608 regulates refrigerant recovery, venting and technician certification.Source: Clean Air Act Section 608; 40 CFR Part 82 Subpart F
Practice question 5 · Ozone and the law
Is it legal to knowingly vent refrigerant during service?
Answer: B. No, intentional venting is prohibited Knowingly venting ozone-depleting refrigerants and their substitutes is prohibited. Only de minimis releases during good-faith recovery are allowed.Source: 40 CFR 82.154
Practice question 6 · Ozone and the law
Which refrigerant is an HCFC?
Answer: C. R-22 R-22 is an HCFC. R-12 is a CFC. R-410A and R-134a are HFCs.Source: EPA refrigerant classifications
Practice question 7 · Ozone and the law
Which refrigerant type contains no chlorine?
Answer: C. HFC HFCs have no chlorine and do not deplete ozone, but many have high global warming potential.Source: EPA refrigerant classifications
Practice question 8 · Ozone and the law
Who may buy refrigerant for servicing equipment?
Answer: D. Certified technicians (with some exceptions such as small cans for car AC) Sales of refrigerant are restricted to certified technicians.Source: 40 CFR 82.154(c)
Recovery, recycling and reclaiming
Practice question 9 · Recovery, recycling and reclaiming
What does "recover" mean?
Answer: B. Remove refrigerant from a system and store it in an external container Recovery means removing it without testing or processing it.Source: 40 CFR 82.152 definitions
Practice question 10 · Recovery, recycling and reclaiming
What does "reclaim" mean?
Answer: C. Reprocess refrigerant to new product purity standards, verified by analysis Reclaimed refrigerant meets AHRI Standard 700, done by EPA-certified reclaimers.Source: 40 CFR 82.152 definitions
Practice question 11 · Recovery, recycling and reclaiming
What colors identify a refrigerant recovery cylinder?
Answer: D. Gray body with a yellow top Recovery cylinders are gray with a yellow top.Source: AHRI Guideline K; DOT requirements
Practice question 12 · Recovery, recycling and reclaiming
How full should a recovery cylinder be filled?
Answer: B. No more than 80% liquid Leave room for liquid expansion. Overfilled cylinders can rupture.Source: DOT and industry safety practice
Practice question 13 · Recovery, recycling and reclaiming
How often must refillable recovery cylinders be hydrostatically tested?
Answer: D. Every 5 years DOT requires a hydrostatic test every 5 years. The test date is stamped on the cylinder.Source: DOT cylinder requirements
Practice question 14 · Recovery, recycling and reclaiming
What should you use to pressurize a system for leak testing?
Answer: B. Dry nitrogen Never use oxygen, which can explode with oil. Nitrogen is the standard.Source: EPA 608 technician training materials
Practice question 15 · Recovery, recycling and reclaiming
Why should you never heat a refrigerant cylinder with an open flame?
Answer: C. Pressure rises with heat and the cylinder can burst Never heat cylinders above 125 degrees F or with a torch.Source: DOT and industry safety practice
Safety and service
Practice question 16 · Safety and service
Why is a large refrigerant leak in an enclosed space dangerous?
Answer: D. Refrigerant is heavier than air and can displace oxygen Refrigerant vapor can cause suffocation. Ventilate, and use oxygen sensors where required.Source: ASHRAE Standard 15; EPA 608 training
Practice question 17 · Safety and service
What PPE is standard when handling refrigerants?
Answer: B. Safety glasses and gloves Liquid refrigerant can freeze skin and eyes on contact.Source: EPA 608 technician training materials
Practice question 18 · Safety and service
How is deep vacuum during evacuation measured?
Answer: A. In microns A micron gauge measures deep vacuum to confirm moisture and air are removed.Source: EPA 608 technician training materials
Practice question 19 · Safety and service
What does the pressure-temperature relationship let a technician do?
Answer: D. Determine refrigerant saturation temperature from pressure P-T charts link pressure to boiling point for each refrigerant.Source: EPA 608 technician training materials
Practice question 20 · Safety and service
Can different refrigerants be mixed in one recovery cylinder?
Answer: B. No, mixed refrigerant may be impossible to reclaim Keep refrigerants separate, one type per cylinder.Source: EPA 608 technician training materials
Certification types
Practice question 21 · Certification types
Which certification covers small appliances with 5 pounds or less of refrigerant?
Answer: B. Type I Type I covers small appliances like refrigerators and window AC units.Source: 40 CFR 82.161
Practice question 22 · Certification types
Which certification covers high-pressure appliances like residential split AC systems?
Answer: D. Type II Type II covers high- and very-high-pressure appliances.Source: 40 CFR 82.161
Practice question 23 · Certification types
Which certification covers low-pressure appliances such as many large chillers?
Answer: B. Type III Type III covers low-pressure appliances.Source: 40 CFR 82.161
Practice question 24 · Certification types
What is Universal certification?
Answer: D. Passing Core plus Type I, II and III Universal means all three types plus Core.Source: 40 CFR 82.161
Practice question 25 · Certification types
How many questions are in each section of the EPA 608 exam, and how many must you get right?
Answer: A. 25 questions, 18 right Each section has 25 questions and requires 18 correct (72%).Source: EPA, Section 608 Technician Certification
Practice question 26 · Certification types
Does EPA 608 certification expire?
Answer: D. No, it does not expire Section 608 certification does not expire. Keep your card or a copy.Source: EPA, Section 608 Technician Certification
Practice score only. This is not an official result and does not predict how you will do on the real exam.
Starting an HVAC business? Homeowners search for HVAC help the moment it gets hot or cold. We list HVAC companies free and build websites that catch those calls.
How to pass: study tips that work
- Master the Core first. You need it for every certification type.
- Know the cylinder rules: gray with yellow top, 80% fill, 5-year hydrostatic test.
- Learn which refrigerants are CFC, HCFC and HFC.
- Use an EPA-approved certifying organization for the real exam.
Official sources to study from
Use the official materials and approved courses as your real guide. These links go to the agencies, not to us.
See a mistake or an outdated rule? Tell us and we will check it against the official source and fix it.
More free practice tests
Common questions
How many questions are on the EPA 608 exam?
Each section (Core, Type I, Type II, Type III) has 25 questions. You need 18 correct to pass a section.
Does EPA 608 certification expire?
No. Section 608 certification does not expire.
Are these real EPA 608 Core exam questions?
No. They are original practice questions written by PITHE Digital Group from public laws, codes and agency guidance. They are not real or past exam questions, and we are not affiliated with the U.S. EPA or any EPA-approved certifying organization or any testing company.
Does passing this EPA 608 Core practice test give me a license or certificate?
No. This free practice test is for study only. You must complete the official requirements and pass the official exam through the agency or its approved provider.
Is this practice test free?
Yes. It is free with no signup. Your progress saves only on your device.
Save this page. Bookmark it (on iPhone tap Share, then Add Bookmark) or send it to someone starting out.
Want customers to find you, too?
List your business free, or get a free website mockup and a written quote from our Pacific Northwest team.