Quick answer
Oregon certifies home inspectors through the CCB, and Washington licenses them through the Department of Licensing. Inspection exams cover structure, exterior, roofing, plumbing, electrical, heating and cooling, and reporting. Key IRC numbers: 6 inches of fall in 10 feet, 7 3/4 inch risers, 34 to 38 inch handrails, guards over 30 inches, 5.7 square foot egress openings.
Practice only. Not an official test.
These are original practice questions written by PITHE Digital Group for study purposes, based on public laws, codes and agency guidance. They are not real or past exam questions, and this page is not affiliated with, endorsed by or sponsored by the Oregon CCB, the Washington State Department of Licensing, the International Code Council or any testing company or any testing company. A score here does not predict your real exam result and does not give you any license, permit, card or certificate.
Laws, codes and fees change, and mistakes are possible. Always confirm with the official agency and your approved course materials. This is general educational information, not legal or professional advice. Read the full disclaimer.
Exam facts are from public agency sources as of November 7, 2026. Confirm current details with the official agency before you schedule.
Thinking about becoming a home inspector or starting an inspection business in the Pacific Northwest? These questions cover the systems and code basics inspectors use daily.
How it works: tap an answer to see if you got it right, why, and the law or code it comes from. Your progress saves on this device only, so you can bookmark the page and pick up later. No signup, no card.
Jump to: Structure and exterior · Stairs, guards and egress · Systems · Oregon and Washington
Structure and exterior
Practice question 1 · Structure and exterior
Under the IRC, how should the ground slope away from a foundation?
Answer: C. At least 6 inches of fall within the first 10 feet The IRC calls for grading that falls at least 6 inches within the first 10 feet, so water drains away from the foundation.Source: International Residential Code (IRC) R401.3
Practice question 2 · Structure and exterior
White, powdery deposits on a concrete or masonry foundation wall are most likely what?
Answer: D. Efflorescence from moisture moving through the masonry Efflorescence is salt left behind as water evaporates. It signals moisture, so look for its source.Source: General home inspection practice
Practice question 3 · Structure and exterior
What is the main purpose of roof flashing?
Answer: A. Directing water away from joints, valleys, chimneys and penetrations Most roof leaks start at flashing. Inspect it at chimneys, walls, valleys, skylights and pipe boots.Source: General home inspection practice
Practice question 4 · Structure and exterior
What is the main purpose of attic ventilation?
Answer: B. Reducing heat and moisture buildup in the attic Good ventilation helps prevent condensation, mold and premature roof wear.Source: IRC R806; general home inspection practice
Practice question 5 · Structure and exterior
Wood siding or trim in direct contact with soil raises the risk of what?
Answer: A. Rot and wood-destroying insects Keep wood clear of soil. The IRC generally calls for clearance between wood and grade.Source: IRC R317; general home inspection practice
Stairs, guards and egress
Practice question 6 · Stairs, guards and egress
What is the maximum riser height for stairs under the IRC?
Answer: C. 7 3/4 inches The IRC limits risers to 7 3/4 inches and requires treads of at least 10 inches.Source: IRC R311.7.5
Practice question 7 · Stairs, guards and egress
What is the minimum tread depth for stairs under the IRC?
Answer: C. 10 inches Treads must be at least 10 inches deep, measured nosing to nosing.Source: IRC R311.7.5.2
Practice question 8 · Stairs, guards and egress
Handrail height on stairs under the IRC is measured from the nosing and must be between what?
Answer: D. 34 and 38 inches Handrails are 34 to 38 inches above the tread nosings.Source: IRC R311.7.8.1
Practice question 9 · Stairs, guards and egress
Residential guards are generally required where a walking surface is more than how high above the floor or grade below?
Answer: C. 30 inches Guards are required where the drop is more than 30 inches, and they are generally at least 36 inches tall.Source: IRC R312.1
Practice question 10 · Stairs, guards and egress
What is the minimum net clear opening for an emergency escape window above the ground floor?
Answer: A. 5.7 square feet Emergency escape openings need 5.7 square feet (5.0 at grade floor), with a sill no higher than 44 inches.Source: IRC R310.2
Practice question 11 · Stairs, guards and egress
What is the maximum sill height for an emergency escape window?
Answer: A. 44 inches The bottom of the clear opening can be no more than 44 inches above the floor.Source: IRC R310.2.2
Systems
Practice question 12 · Systems
Two wires connected under one breaker terminal that is not rated for two is called what?
Answer: A. A double tap Many breakers are listed for only one conductor. Report double taps for evaluation by an electrician.Source: General home inspection practice; NEC 110.3(B)
Practice question 13 · Systems
Where should GFCI protection be present in a home?
Answer: D. Bathrooms, kitchens, garages, outdoors and other wet or damp areas Test GFCIs where required. Missing protection is a common safety finding, even if the home predates the rule.Source: NEC 210.8(A)
Practice question 14 · Systems
The water heater's T&P relief valve discharge pipe is capped. What should the inspector do?
Answer: B. Report it as a safety defect A blocked relief line defeats the safety valve. Report it as a safety concern.Source: Uniform Plumbing Code; general home inspection practice
Practice question 15 · Systems
Where are carbon monoxide alarms generally required?
Answer: D. In homes with fuel-burning appliances or attached garages, outside sleeping areas CO alarms are required in many situations, including homes with fuel-burning appliances or attached garages. Oregon and Washington have their own CO alarm rules for sales and rentals.Source: IRC R315; Oregon and Washington CO alarm laws
Practice question 16 · Systems
What does a home inspector typically do with a component that cannot be safely accessed?
Answer: A. Report that it was not inspected and why Standards of practice require you to disclose what was not inspected and the reason.Source: Typical home inspection standards of practice (ASHI, InterNACHI)
Oregon and Washington
Practice question 17 · Oregon and Washington
Which agency certifies home inspectors in Oregon?
Answer: B. The Construction Contractors Board (CCB) Oregon home inspectors are certified through the CCB.Source: Oregon CCB, Home Inspector Program
Practice question 18 · Oregon and Washington
Which agency licenses home inspectors in Washington?
Answer: B. The Department of Licensing (DOL) Washington DOL licenses home inspectors.Source: Washington State Department of Licensing, Home inspectors
Practice question 19 · Oregon and Washington
What is a home inspection?
Answer: A. A visual, non-invasive look at the home's readily accessible systems and components It is visual and limited. It is not a warranty, appraisal or code inspection.Source: Typical home inspection standards of practice
Practice score only. This is not an official result and does not predict how you will do on the real exam.
Starting your inspection business? Realtors and buyers search online for inspectors. We list inspectors free and build websites that book inspections.
How to pass: study tips that work
- Know the IRC numbers for stairs, guards, egress and grading.
- Practice describing defects clearly: what it is, where, why it matters, who should fix it.
- Study your state's standards of practice.
Official sources to study from
Use the official materials and approved courses as your real guide. These links go to the agencies, not to us.
See a mistake or an outdated rule? Tell us and we will check it against the official source and fix it.
More free practice tests
Common questions
Who licenses home inspectors in Oregon?
The Oregon Construction Contractors Board certifies home inspectors.
Who licenses home inspectors in Washington?
The Washington State Department of Licensing.
Are these real Home inspector exam questions?
No. They are original practice questions written by PITHE Digital Group from public laws, codes and agency guidance. They are not real or past exam questions, and we are not affiliated with the Oregon CCB, the Washington State Department of Licensing, the International Code Council or any testing company or any testing company.
Does passing this Home inspector practice test give me a license or certificate?
No. This free practice test is for study only. You must complete the official requirements and pass the official exam through the agency or its approved provider.
Is this practice test free?
Yes. It is free with no signup. Your progress saves only on your device.
Save this page. Bookmark it (on iPhone tap Share, then Add Bookmark) or send it to someone starting out.
Want customers to find you, too?
List your business free, or get a free website mockup and a written quote from our Pacific Northwest team.